Instaleaza gratuit aplicatia pentru Android
CONSTRUCTII
  • Toata tara
    CAUTA

    . Termostat aplicatii exterioare

    131 RON
    MesajFavorite
    Alerta pret


    Adaugat la data de 29 Mai 2012 13:25 - ID: 441209  
    DESCRIERE
    Termostat AT-TS-13
      
      
      Interval de temperaturã reglabil: de la –5 �C la +15 �C
      Termostat de control pentru detectarea abaterilor sau termostat de ambient
      Valoarea maxima a curentului nominal 16 A la 250 Vac
      AT-TS-13 AT-TS-14
      General
      Area of use Ordinary area, outdoors Ordinary area, outdoors
      Supply voltage 230 VAC +10% –15% 50/60 Hz 230 VAC +10% –15% 50/60 Hz
      Max. switching current 16 A, 250 Vac 16 A, 250 Vac
      Max. conductor size 2.5 mm2
      2.5 mm2
      Switching differential 0.6 K to 1 K 0.6 K to 1 K
      Switching accuracy � 1 K at 5 �C (calibration point) 2 K at 60 �C (calibration point)
      Switch type SPST (normally open) SPST (normally open)
      Adjustable temperature range –5 �C to +15 �C 0 �C to +120 �C
      Housing
      Temperature setting inside inside
      Exposure temperature –20 �C to +50 �C –20 �C to +50 �C
      Ingress protection IP65 according to EN 60529 IP65 according to EN 60529
      Entries 1 x M20 for supply cable (ø8-13 mm) 1 x M20 for supply cable (ø8-13 mm)
      1 x M25 for heating element (ø11-17 mm) 1 x M25 for heating element (ø11-17 mm)
      1 x M16 for the sensor 1 x M16 for the sensor
      Material ABS ABS
      Lid fixing nickel-plated quick release screws nickel-plated quick release screws
      Mounting SB-110 and SB-111 SB-110 and SB-111
      or surface mount or surface mount
      
      AT-TS-13 AT-TS-14
      Temperature sensor (HARD-69)
      Type PTC KTY 83-110 PTC KTY 83-110
      Length sensor cable 3 m 3 m
      Diameter sensor cable 5.5 mm 5.5 mm
      Diameter sensor head 6.5 mm 6.5 mm
      Max. exposure temperature sensor cable 160 �C
      The sensor cable may be extended to a maximum of 100 m using a 2-conductor wire
      with a a cross-section of 1.5 mm2
      The sensor cable should be shielded if it is laid in .
      cable ducts or in the vicinity of high-voltage carrying cables. The shield of the extension
      cable should be grounded at the controller end only.
      Out put parameters
      Alarm on LED Green LED: Heating Cable ON Green LED: Heating Cable ON
      Red LED: Sensor break Red LED: Sensor break
      Red LED: Sensor short-circuit Red LED: Sensor short-circuit
      Ordering details
      Part description AT-TS-13 AT-TS-14
      PN (Weight) 728129-000 (440 g) 648945-000 (440 g)
      Accessories
      PA Reducer REDUCER-M25/M20-PA REDUCER-M25/M20-PA
      M25 male/M20 female M25 male/M20 female
      PN 184856-000 184856-000
      Temperature sensor HARD-69 HARD-69
      PN (Weight) 133571-000 (180 g) 133571-000 (180 g


    IMAGINI


    MESAJ


    COMENTARII SI RECENZII
    29 Mai 2012  ·  Valabilit. 28 Mai 2017  ·  Afisari : 21  ·  Modificati anuntul  · Semnalati o neregula     




    TOTAL HEAT S.R.L.
    COMERCIANTI
    Membru de 14 ani · Online acum 1 an
    0 abonati


    Home · Adauga anunt · Modifica anunt · Login · Inregistrare firma · Forum · Widget anunturi · Semnalati o neregula · Contactati echipa Anunturi AZ ·

    Index produse:   A   B   C   D   E   F   G   H   I   J   K   L   M   N   O   P   Q   R   S   T   U   V   X   Y   Z
    Descarca gratuit aplicatia pentru telefonul tau


    Va doriti propriile produse listate aici ? Creati-va propriul magazin virtual pe aaz.ro.

    Informatiile despre preturi, produse si servicii sunt oferite de terte parti si doar pentru informare. AAZ.ro nu garanteaza acuratetea informatiilor si nu este raspunzator pentru nici o eroare, omisiune sau intarzieri,
    nici pentru orice neintelegeri sau pierderi datorita acestor informatii. Termeni si conditii | Politica de confidentialitate | Stergerea contului | Cookies | Siguranta online | ANPC | Contact



    Verified by VISA MasterCard SecureCode
    AAZ.ro © 2008